Floating
27
charging
voltage
Low DC cut-
29
off voltage
Solar power
balance:
When
31
enabled, solar
input power
will be
automatically
EN
If self-defined is selected in program 5, this program
can be set up. Setting range is from 24.0V to 29.2V for
1000VA/2000VA model and 48.0V to 58.4V for 4000VA
model. Increment of each click is 0.1V.
1000VA/2000VA default setting: 27.0V
4000VA default setting: 54.0V
If self-defined is selected in program 5, this program
can be set up. Setting range is from 24.0V to 29.2V for
1000VA/2000VA model and 48.0V to 58.4V for 4000VA
model. Increment of each click is 0.1V.
1000VA/2000VA default setting: 21.0V
4000VA default setting: 42.0V
If self-defined is selected in program 5, this program
can be set up. Setting range is from 20.0V to 24.0V for
1000VA/2000VA model and 40.0V to 48.0V for 4000VA
model. Increment of each click is 0.1V. Low DC cut-off
voltage will be fixed to setting value no matter what
percentage of load is connected.
Solar power balance:
Enable (default)
If selected, solar input
power will be
automatically adjusted
according to the following
formula:
Max. input solar power =
Max. battery charging