General safety precautions
Warning: incorrect installation may cause severe
damage or injury. Read the instructions carefully before
installing the product.
This installation manual is intended for qualified personnel only.
ROGER TECHNOLOGY cannot be held responsible for any damage
or injury due to improper use or any use other than the intended
usage indicated in this manual.
Installation, electrical connections and adjustments must be
performed by qualified personnel, in accordance with best
practices and in compliance with applicable regulations. Before
installing the product, make sure it is in perfect condition.
Disconnect the mains electrical power before performing any
work.
Only use original spare parts when repairing or replacing products.
The packaging materials (plastic, polystyrene, etc.) should not be
discarded in the environment or left within reach of children, as
they are a potential source of danger.
WARNING! Handle electronic parts and terminals with extreme
care, as these parts are highly sensitive to static electricity.
Handle the LED light strip with extreme care. Do not twist, pull,
tread on, bend or drill the strip casing.
2
Product description
The lights for the arm of the ROGER BIONIK barrier make the arm
more visible in all conditions.
They are composed of a LED strip that is inserted inside the
boom.
By configuring the command unit they are connected to, it is
possible to configure the start-up procedure (parameter
They are supplied in 4 sizes:
• ALED/4C: Strip LED 4 metres with connections cable.
• ALED/4C/RGB: Strip LED RGB 4 metres with connections cable.
• ALED/6C: Strip LED 6 metres with connections cable.
• ALED/6C/RGB: Strip LED RGB 6 metres with connections cable.
• ALED/8C: Strip LED 8 metres with connections cable.
• ALED/8C/RGB: Strip LED RGB 8 metres with connections cable.
• ALED/12C: Strip LED 12 metres with connections cable.
• ALED/12C/RGB: Strip LED RGB 12 metres with connections cable.
3
Technical specifications
MAINS POWER VOLTAGE
MAXIMUM MAINS POWER
ABSORPTION
(*)
the
indicated
power
corresponds to the three colours
(R, G, B) switched on at the same
time, with steady light (situation
not managed in any case). In the
case of green or red light, the
power is to be divided by 3.
OPERATING TEMPERATURE
DEGREE OF PROTECTION
PRODUCT DIMENSIONS
ALED/4C 15x6x4500 mm - ALED/4C/RGB 15x6x4500 mm
ALED/6C 15x6x7500 mm - ALED/6C/RGB 15x6x7500 mm
ALED/8C 15x6x9500 mm - ALED/8C/RGB 15x6x9500 mm
ALED/12C 15x6x13500 mm - ALED/12C/RGB 15x6x13500 mm
WEIGHT
ALED/4C 0,22 kg - ALED/4C/RGB 0,32 kg
ALED/6C 0,29 kg - ALED/6C/RGB 0,39 kg
ALED/8C 0,37 kg - ALED/8C/RGB 0,47 kg
ALED/12C 0,52 kg - ALED/12C/RGB 0,62 kg
18
).
79
24 V
±10%
4W
ALED/4C
14W
ALED/4C/RGB *
5W
ALED/6C
21W
ALED/6C/RGB *
7W
ALED/8C
28W
ALED/8C/RGB *
10W
ALED/12C
42W
ALED/12C/RGB *
-20°C
+55°C
IP54
4
Installation
4.1
Adjusting length
If necessary, the LED light strip must be shortened.
1. Detach and remove the terminal black cap (A fig. 1).
2. Cut at the contacts + 24V - + 24V / GND-GND (detail B).
ATTENTION: DO NOT CUT at the contacts + 24V - + 24V /
A - B / GND - GND.
NB: It is possible to cut the LED light strip every 1000 mm.
3. Fix the terminal black cap (C) onto the strip with silicone
sealant.
Proceed with the installation as indicated in the following
chapters, based on the installed barrier model.
Whenever corrective actions are carried out, pay
the utmost attention when releasing, locking or
moving the internal mechanical parts. These operations
could be hazardous for the user.
WARNING: only perform the installation procedures
with the unit disconnected from mains and with the
motor at a standstill.
4.2
Installation procedure BIONIK4
If the arm is mounted on the barrier's body, remove it.
Place the arm on a stable surface, making sure it is not scratched.
To insert the LEDs, proceed as follows (Fig. 2):
• Undo the 4.2x19 mm self-tapping cylindrical socket head cap
screws from the boom mount.
• Remove the boom mount cover (detail D).
• Undo the 4.2x13 mm cylindrical socket head cap screws and
remove the boom end cap (detail E).
• Feed the LED light strip [F] into the PVC moulding until it
comes out at the other end.
• Fold the excess length of LED light strip, push it into the
aluminium moulding and fasten with the cable tie included
(detail G).
• Route the cable of the LED light strip correctly [H] as shown
in figure 3.
• Secure the cable with the relative cable fasteners [I].
• Feed the cable in the hole in the centre of the boom mount [L].
• Push the LED light strip cable out of the opposite end of the
gear motor unit [M], securing with the cable fastener included
[N] (fig. 4).
• Feed the cable into the control unit, ensuring that the cable will
not interfere with the movements of the automation system.
FOR ALED LIGHT CONNECTIONS: connect the cable to the control
unit as shown in fig. 5. Connect the brown (or red) wire to the
+LUCI terminal and connect the blue (or black) wire to the COM
terminal.
Refer to parameter 79 of the control unit for setting up the LED
light strip.
FOR ALED/RGB LIGHT CONNECTIONS: make connections with
ALED/RGB and refer to RGB light operation modes see figure 13
and installation manual B73/LTM.
4.3
Installation
BIONIK4HP-BIONIK6
If the arm is mounted on the barrier's body, remove it.
Place the arm on a stable surface, making sure it is not scratched.
To insert the LEDs proceed as follows (figure 5):
• Unscrew the 6 M8 screws and remove the boom support
cover.
• Unscrew the screws and remove the cap of the boom (detail D).
• Remove the two transparent side profiles.
• Ensuring that the LEDs are facing outwards (detail E), insert
the LED strip into the two transparent profiles by gently
procedure