Descargar Imprimir esta página

tau K996MA Guía Para La Instalación página 16

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

DL3
SENSITIVE EDGE green LED signal
DL4
Radio receiver programming red LED signal
DL5
ERRORS red LED signal
9. K996M CHARACTERISTICS
LED - DL5
The LED, besides indicating that the power supply is connected, also signals errors with a series of
pre-defined flashes:
steady light:
normal operation;
1 flash:
buffer battery voltage lower than 11.3 Vdc;
Check the mains power supply, charge the battery, replace the battery;
3 flashes:
power failure;
Check the thermal-magnetic circuit breaker (upstream from system), check the fuses;
4 flashes:
max current limit exceeded;
Gearmotor has exceeded absorption limits, check for obstacles across the path of the overhead door, check
the current absorption of the motor when loadless and under load;
5 flashes:
absence of encoder signal;
Check wiring, check encoder through TEST-ENCODER (optional)
6 flashes:
presence of obstacle after 5 failed attempts to close;
Make sure there are no obstacles across the path of the overhead door and that it slides smoothly;
7 flashes:
no memorization procedure has been executed;
Execute memorization procedure.
8 flashes:
no motor signal.
check wiring, check that the motor rotates freely when powered directly by battery, check fuse F2.
Multiple errors are signalled by a 2-second pause between signals.
If the encoder is activated 5 consecutive times during the same closing manoeuvre (obstacle detection),
the control unit opens completely indicating the error with the provided series of
manoeuvre, the control unit will stop flashing and will switch to slow-down mode as it searches for the
closing travel limit.
If the sensitive edge are activated 5 consecutive times during the same closing manoeuvre (obstacle
detection), the control unit opens completely and stops without flashing.
noeuvre, you need a new command.
COURTESY LIGHT (18 Vdc - max. 15W)
The open gate indicator light comes on when an open command is given, and it stays on throughout
the manoeuvre and during the pause time; it goes off 2 minutes after the gate has closed.
BATTERY CHARGER BOARD (OPTIONAL)
If the system is equipped with a battery charger board, it con operate even during power failures. If
the voltage drops below 11.3 Vdc, the automation stops working (the control panel is still powered).
When it drops below 10.2 Vdc, the board disconnects the battery completely (the control panel is no
longer powered).
OBSTACLE DETECTION
If the obstacle detection function (which can be set through trimmer FR) is activated during an open-
ing manoeuvre, the gate closes approx. 20 cm., if it is activated during a closing manoeuvre, the gate
opens all the way .
WARNING: the control panel logics may interpret mechanical friction as an obstacle.
SLOW-DOWN
To prevent the gate from shuddering at the end of its travel, you can set (through the RALL trimmer) the
slow down function for the opening and closing manoeuvres at a distance of 10 to 100 cm from the end
All manuals and user guides at all-guides.com
To complete the closing
16
flashes. On the next
ma-

Publicidad

loading