Information
3mm
●
Sufficient air is needed for proper combustion and exhaustion of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Ductless fans must
always be vented to the outdoors.
●
When assessing the air pressure, the entire ventilation system in the house/apartment
must be taken into account, e.g. hob and/or gas cooker, this rule does not apply.
●
Government regulations must be observed for the conveyance of exhaust air. If the
extractor hood is used in circulating air mode with activated carbon filter, there are no
operating restrictions.
●
If you choose extraction-air mode, there are two methods for ventilation, including
'horizontal ventilation' and 'vertical ventilation'. Please use tool take out the cover
before using and install check valve on the hole.
●
The square air check valve for horizontal ventilation is not supplied.
3mm
Prepare the installation:
Ensure the power has been turned off before beginning this installation. Plug must be assembled in
places easy to drag and insert.
To install this hood you will require two assistants. You will need following tools and material to
complete this installation.
Tools you will need:
●
Drill appropriate to your wall
●
Phillips Screwdriver
●
Tape Measure
●
Hand Saw or Jig Saw
6mm
●
Installation work and electrical wiring must be
done by qualified person(s) in accordance
with all applicable codes and standards,
including fire rated construction.
●
Do not discharge the exhaust air into a flue
from other appliances burning gas or other
fuels.
●
Regulations concerning the discharge of air
have to be fulfilled.
●
The cooker hood must be placed at a
minimum distance of 65cm above the
cooking surface of a hob.
●
The cooker hood must be placed at a
maximum distance of 75cm above the
cooking surface of a hob.
3mm
597mm
Min. 650mm
Max. 750mm
6