7. Open the valve on the water mains.
8. Bleed the system before you operate the product.
To bleed the system on page 23 .
Refer to
To connect the product to an open water
source
The product can be used with water from an open water
source, for example a lake or a water barrel. Use a ½ in.
suction hose (not included) that is maximum 3 m long.
(Fig. 47)
CAUTION:
the water source must not be more than
20°C.
CAUTION:
more than 0.5 m above the water source.
1. If the garden hose adapter is installed, remove it
from the water inlet on the product. (Fig. 48)
CAUTION:
filter in the water inlet.
2. Connect a suction hose (not included) to the water
inlet on the product. (Fig. 49)
3. Put the suction hose in the water source and make
sure that the filter is fully submerged.
CAUTION:
hose without a filter.
4. Push the tab in the direction of the quick connection
on the spray handle and pull out the high-pressure
water hose.
a) PW 350 (Fig. 23)
b) PW 360 and PW 370 (Fig. 24)
5. Connect the power plug to a power source.
6. Turn the power switch to the on (I) position and let
the product operate for 2 minutes.
7. Turn the power switch to the off (0) position.
8. Hold the spray handle tightly with one hand and
push the high-pressure water hose into the quick
connection on the spray handle.
a) PW 350 (Fig. 21)
b) PW 360 and PW 370 (Fig. 22)
9. Bleed the system before you operate the product.
To bleed the system on page 23 .
Refer to
2167 - 004 - 18.12.2023
The water temperature in
The product must not be
Do not remove the water
Do not use a suction
To bleed the system
CAUTION:
switch is in the off (0) position before you
bleed the system.
1. Connect the product to a water source. Refer to
connect the product to a water source on page 22 .
2. Install the spray lance on the spray handle. Refer to
To install the spray lance on page 21 .
3. Disengage the power trigger lockout. Refer to
engage and disengage the power trigger lockout on
page 23 .
4. Push the power trigger and keep it pushed in until
water comes out of the nozzle on the spray lance.
a) PW 350 (Fig. 50)
b) PW 360 and PW 370 (Fig. 51)
To disconnect the product from the water
source
1. Turn the power switch to the off (0) position.
2. If the product is connected to the water mains, close
the valve on the water mains.
3. If the product is connected to the water mains,
disconnect the garden hose from the water mains.
(Fig. 52)
4. If the product is connected to an open water source,
remove the suction hose from the water source.
5. Push the power trigger and keep it pushed in until no
water comes out of the nozzle.
6. Disconnect the garden hose from the water inlet on
the product.
7. If the product is connected to an open water source,
disconnect the suction hose. (Fig. 53)
8. Push the tab in the direction of the quick connection
on the spray handle and pull out the high-pressure
water hose.
a) PW 350 (Fig. 23)
b) PW 360 and PW 370 (Fig. 24)
9. Turn the power switch to the on (I) position. Let the
product operate until no water comes out of the high-
pressure hose.
10. Turn the power switch to the off (0) position.
11. Let the spray handle, the spray lance, and the
nozzles become dry before you put the product in
storage.
To engage and disengage the power
trigger lockout
•
To engage the power trigger lockout, push the button
to the locked position.
a) PW 350 (Fig. 54)
b) PW 360 and PW 370 (Fig. 55)
Make sure that the power
To
To
23