Installation (continued)
9
Preparing the location (wall mounting)
□ Determine de distance from the cooking surface to mounting
holes.
□ Taking as base the horizontal line and the center line of the wall,
mark the location of the four keyhole mounting slots, as shown.
13-5/16 in. (33.78 cm)
3-7/8 in.
(9.85 cm)
5/16 in.
7-3/16 in. (20.12 cm)
(.79 cm)
Pilot Holes
Safety Holes
NOTE: Make the drill holes on the thin area of the slot.
1
1. Drill Pilot Hole
2. Drill Safety Hole
□ Use a 3/10 in. (8 mm) drill bit and drill two pilot holes (1) and
two safety holes (2).
□ Insert four wall anchors (BB) in those holes.
□ Install the two of the 5 x 45 mm upper mounting screws (CC)
in pilot holes. Leave about 1/4 in. (6.4 mm) space between
screw heads and wall to slide range hood into place.
NOTE: Leave the safety holes without screws.
NOTE: If the wall is wood, do not use anchors (use 3mm drill).
Distance from
cooking surface
Centerline
2
CC
BB
1/4
in.
(6.4 mm)
10
Installing power supply cable
□ For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards and
local codes and ordinances. There must be enough wiring
from the fused disconnect (or circuit breaker) box to make the
connection in the hood electrical terminal box.
NOTE: Do not reconnect power until the installation is
complete.
□ Remove the power supply knockout (1) from the top or rear
of the vent hood (depending on the incoming location of your
home power supply cable) and install a UL listed or CSA
approved 1/2 in. strain relief (not included).
1
□ Lift the hood into final position (see Installation section steps
11 or 12 depending the kind of installation you need). Feed
enough electrical wire through the 1/2 in. UL listed or CSA
approved strain relief to make connections in the terminal box.
Tighten the strain relief screws.
□ Connect ventwork to hood. Seal joints with vent clamps or duct
tape to make secure and airtight.
□ Check that back draft dampers work properly.