Descargar Imprimir esta página

CORBERO CTMA50H Manual De Instrucciones página 4

Termo eléctrico de almacenamiento sellado

Publicidad

Idiomas disponibles

Idiomas disponibles

If any parts and components of this electrical water heater are damaged please contact customer
care center for repair.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
The maximum inlet water pressure is 0.5MPa; the minimum inlet water pressure is 0.1MPa, if this
is necessary for the correct operation of the appliance.
The water may drip from the discharge pipe of the pressure-relief device and that this pipe must be
left open to the atmosphere; The pressure-relief device is to be operated regularly to remove lime
deposits and to verify that it is not blocked;
In order to drain away the water inside the inner container, it can be drained away from the pressure
release valve. Twist the thread screw of the pressure release valve off, and lift the drain handle
upwards.(See Fig.1) A discharge pipe connected to the pressure-relief device is to be installed in a
continuously downward direction and in a frost-free environment.
2. PRODUCT INTRODUCTION
2.1 Technical Performance Parameters
Model
CTMA50H
CTMA80H
Rated
Rated
Volume
Power
Voltage
(L)
(W)
(ACV)
47
1500
220-240
74
1500
220-240
Rated
Max Of Water
Pressure
Temperature
(MPa)
(℃)
0.75
75
0.75
75
3
Protection
Waterproof
Class
Grade
I
IPX4
I
IPX4