Descargar Imprimir esta página

Lamborghini Caloreclima ALHENA C Instrucciones De Uso, Instalación Y Mantenimiento página 248

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ALHENA C
Recommended chemical conditioners:
SENTINEL X100 and SENTINEL X200
FERNOX F1 and FERNOX F3
The unit is equipped with a frost protection system that activates the boiler in heating mode
when the system flow water temperature falls below 6°C. The device is not active if the
power and/or gas supply to the unit is turned off. If necessary, to protect the system use a
suitable antifreeze liquid that meets the above requirements and provided for by UNI 8065.
In the presence of adequate chemical/physical system and feed water treatments and re-
lated high cyclicity controls able to ensure the required parameters, for industrial process
applications the product can be installed in open-vessel systems with vessel hydrostatic
height able to ensure compliance with the minimum operating pressure indicated in the
product technical specifications.
The presence of deposits on the boiler exchange surfaces due to non-compliance
with the above requirements will involve non-recognition of the warranty.
2.4 Gas connection
Before making the connection, ensure that the unit is
B
arranged for operation with the type of fuel available.
The gas connection must be made to the relevant con-
nection (see fig. 52 and fig. 56) in compliance with cur-
rent legislation, using a rigid metal pipe or a
continuous wall flexible hose in stainless steel, pla-
cing a gas valve between the system and boiler. Make
sure all the gas connections are tight. Otherwise there
may be a risk of fire, explosion or suffocation.
248
EN
cod. 3540000251 - Rev. 00 - 03/2024

Publicidad

loading

Este manual también es adecuado para:

Alhena 24 cAlhena 28 cAlhena 34 c0tpf2awd0tpf4awd0tpf7awd