Descargar Imprimir esta página

Metabo AS 36-18 L 20 PC Manual Original página 18

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
en
ENGLISH
filtered forced ventilation. Then
clean the maintenance area.
Do not operate the device without
the complete filtration system.
(filter cassettes and special filter
bags H-class).
According to tests carried out as
per EN 60335 section 1 and 2- 69,
the device also meets electrical
safety requirements relating to the
extraction of a water-air mixture.
WARNING - Do not reuse the filter
cassettes after they have been
removed from the machine.
Special safety instructions for
AS 36-18 L 20 PC,
AS 36-18 L 20 PC-CC,
AS 36-18 L 30 PC-CC:
Warning sign for machines with
dust class L:
While the device is suitable for
extracting substances that pose a
slight threat to health, it is not
appropriate for reducing wood dust
in inhaled air.
Dust from material such as paint
containing lead, some wood
species, minerals and metal may
be harmful. Contact with or
inhalation of the dust may cause
allergic reactions and/or
respiratory diseases to the
operator or bystanders.
Certain kinds of dust are classified
as carcinogenic such as oak and
beech dust especially in
conjunction with additives for wood
conditioning (chromate, wood
preservative).
18
If the extracted air is discharged
into the room, ensure there is an
adequate air change rate (L) in the
room. Observe the regulations that
apply in your country.
Caution! This device contains
dust that is harmful to health.
Discharge and maintenance
operations (including disposal of
the dust collection containers)
must only be carried out by
qualified specialists wearing
appropriate protective clothing and
equipment.
6. Special safety instructions for
battery packs
Before fitting the battery pack,
make sure that the machine is
switched off.
Remove the battery pack from the
machine before making any
adjustments, changing tools,
maintaining or cleaning.
Protect battery packs from
water and moisture!
Do not expose battery packs
to fire!
Do not use faulty or deformed
battery packs!
Do not open battery packs!
Do not touch or short circuit battery
pack contacts!
A slightly acidic, flammable
fluid may leak from defective
Li-Ion battery packs!
If battery fluid leaks out and
comes into contact with your
skin, rinse immediately with
plenty of water. If battery fluid leaks
out and comes into contact with
your eyes, wash them with clean
water and seek medical attention
immediately!