If the trouble you are experiencing is not listed in this table or you are unable to rectify the problem by
yourself, please contact Hilti Service.
Trouble or fault
Status indicator flashes
green.
Status indicator flashes blue-
red.
The fastener guide cannot
be pressed in and the status
indicator shows green.
The fastener guide cannot
be pressed in and cannot be
released.
The fastener guide is jammed
in the pressed-in state.
The spring element is not ten-
sioned, the status indicator
flashes green and 1 battery
charge status LED flashes.
There is a delay before the
spring mechanism is ten-
sioned, the status indicator
flashes blue and a signal tone
is emitted simultaneously; the
status indicator then shows
blue for 6 minutes.
Spring element is not re-
tensioned and status indi-
cator flashes yellow.
The spring element is not ten-
sioned and the status indica-
tor flashes red.
The spring element is not ten-
sioned and the status indica-
tor shows red.
The spring element is not ten-
sioned; no status indication.
LEDs of the battery show
nothing.
*2360185*
Possible cause
The battery is empty.
Battery temperature too high.
Wrong nails in the magazine.
The magazine is empty.
The nail pusher is jammed.
Nail jammed in the fastener guide.
Fastener guide jams
Dirt between the fastener guide
and the nosepiece.
The battery is empty.
Battery temperature too low.
The magazine is empty.
The fastening tool has overheated.
The fastener guide is not fitted
correctly.
Magazine not inserted correctly.
System fault.
The battery is empty.
The battery is not fitted correctly.
Deep discharge protection is ac-
tive.
Battery defective.
2360185
Action to be taken
▶ Change the battery.
▶ Allow the battery to cool down.
▶ Insert genuine Hilti nails into the
magazine.
▶ Contact Hilti Service if the fault
/ error persists.
▶ For magazine operation, load
the magazine. → page 13
▶ Remove the nail strips from
the magazine and clean the
magazine.
▶ Release the jammed nail.
→ page 15
▶ Have the tool repaired by Hilti
Service.
▶ Clean the inside of the nose-
piece. → page 16
▶ Contact Hilti Service if the fault
/ error persists.
▶ Change the battery.
▶ Allow the battery to warm up
slowly to room temperature.
▶ For magazine operation, load
the magazine. → page 13
▶ Allow the fastening tool to cool
down.
▶ Insert the fastener guide.
→ page 12
▶ Remove the magazine .
→ page 12 Re-insert the
magazine . → page 12
▶ Remove the battery and then
re-insert the battery.
▶ Consult Hilti Service.
▶ Change the battery.
▶ Remove and then correctly
reinsert the battery. → page 11
▶ Remove and then reinsert the
battery.
▶ Contact Hilti Service.
English