(9) Abnormity and Solution
Fault
Light on, but motor does not
work
Light does not work, motor
does not work
Oil leakage
Shake of the body
Insufficient suction
The machine inclines
Cause
The leaf blocked
The capacitor damaged
The motor jammed bearing damaged
The internal with of motor off or a bad
smell from the motor
Beside the above mentioned, check the following:
Light damaged
Power cord looses
One way valve and the air ventilation
entrance are not tightly sealed
Leakage from the connection of
U-shaped section and cover
The
leaf
damaged
shaking
The motor is not tightly hanged
The body is not tightly hanged
The distance between the body and
the gas top too long
Too much ventilation from open doors
or windows
The fixing screw not tight enough
The hanging screw not tight enough
Get rid of the blocking
Replace capacitor
Replace motor
Replace motor
Replace lights
Connect the wires as per the
electric diagram
Take down the one way valve
and seal with glue
Take U-shaped section down
and seal with soap or paint
and
causes
Replace the leaf
Lock the motor tightly
Fixed the body tightly
Readjust the distance
Choose
resemble the machine
Tighten the hanging screw and
make it horizontal
Tighten the hanging screw and
make it horizontal
29