Solution Filter Cleaning; Machine Speed Adjustment - Clarke Vantage 17 B Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SOLUTION FILTER CLEANING

1.
Drive the machine on a level floor.
2.
Make sure that the switches (62 and 63) are turned to "0".
3.
Close the solution valve (A, Fig. 9) under the machine, in front of the left rear wheel.
The valve (A) is closed when it is in the position (B) and it is open when it is in the position (C).
4.
Remove the transparent cover (D) and the gasket (E), then remove the filter strainer (F). Clean and install them on the support (G).
NOTE
Install the gasket (E) and the filter strainer (F) properly on the cover (D) and on the support (G).
5.
Open the valve (A) by turning it to position (C).

MACHINE SPEED ADJUSTMENT

NOTE
The machine speed varies according to the type of floor to be cleaned and the choice of using the brush or the pad.
If necessary, perform the following procedure.
1.
Adjust the machine speed with the handwheel (53) according to the following procedure:
Turn it counter-clockwise to increase the machine speed.
Turn it clockwise to decrease the machine speed.
2.
If it is difficult to keep the machine moving straight-forwardly because it deviates to the left or to the right, adjust the handwheel
(52) by turning it clockwise or counter-clockwise.
3.
With the machine ready to operate, perform hands-on tests of the machine and other adjustments if necessary.
C
A
B
Figure 9
9099650000 - VANTAGE 17 B
INSTRUCTIONS FOR USE
G
F
E
D
ENGLISH
P100646
21

Publicidad

Tabla de contenido
loading

Tabla de contenido