socket before emptying the basket, replacing the UV lamp, or carrying out other mainte-
nance.
Keep the appliance away from sources of moisture and water. Never immerse the appliance
in water or any other liquid.
Do not insert fi ngers or other objects into the lamp when powered on.
Set the lamp in a place ensuring free air fl ow and where the UV lamp light is easily visible to
insects.
OPERATING THE LAMP
Preparing for operation
Unpack the appliance by removing all packaging components. The covers can be secured during transport with adhesive tape
which should be removed. Clean the external surfaces of the appliance according to the instructions contained in the "Appliance
maintenance" section. Set the appliance according to the instructions.
The lamp can be hanged. Use the hook located on the top of the lamp for hanging. Use the chain provided (II) for hanging the
lamp. The location of hanging the lamp should be chosen so as to minimise the impact of wind.
Turning the lamp on/off
Place the lamp in the place of use according to the recommendations.
Turn the lamp on by moving the switch to the "on" position – I. The UV light will light up.
The lamp is turned off when the power switch is set to the off position – O. The UV tube light will go out.
UV tube light replacement
Warning! Make sure the appliance is disconnected from the power supply before replacing the UV tube light. The power cord
plug is unplugged from the socket.
The UV tube light is located behind the mesh cover. Remove the mesh holders by unscrewing the fi xing screws. Remove the
mesh. Wear gloves while replacing the tube lights. Turn the tube and pull it out of the sockets. Insert a new tube into the sockets
on both sides and then turn it. After replacing the tube light, the lamp must be assembled.
Lamp maintenance
Warning! Before maintenance, make sure that the appliance is disconnected from the power supply. The power cord plug is
unplugged from the socket.
The container and tubes can be cleaned with a soft brush or a brush with plastic bristles. Be careful not to damage the components
while cleaning. Clean other parts of the lamp with a damp cloth, then dry or leave them to dry. Do not immerse the lamp in water
or any other liquid.
TECHNICAL DATA
Parameter
Catalogue No.
Rated voltage
Rated frequency
Rated power
Protection class
UV lamp wavelength
Operation area
Protection rating
Weight
Tube light type
O R I G I N A L
8
EN
Unit
Value
67032
[VAC]
220-240
[Hz]
50
[W]
17
II
[nm]
365
[m
]
30
2
IPX0
[kg]
1.31
2 x T5-6W / 67054
I N S T R U C T I O N S
Value
67033
220-240
50
26
II
365
80
IPX0
1.85
2 x T8-10W / 67055
2 x T8-18W / 67056
Value
67034
220-240
50
41
II
365
150
IPX0
2.59