32
Maintenance and Service
Error Code
EN
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E26
E27
E28
USER MANUAL
Error
Torch Connection
• The torch or torch connections
Error
may be faulty
System Error
• There may be a hardware error
Wire Feeder Error
• There may be an error in wire feeding
System Error
• There may be a hardware error
Remote Control
• There may be an error in the remote
Communication
control connections
Error
System Error
• There may be a hardware error
• The duty cycle of your machine may
have been exceeded
• Fan may not be working
Thermal
Protection
(Secondary)
• The front of the air inlet - outlet ducts
may be blocked
• The machine working environment
may be too hot or stuffy
System Error
• There may be a hardware error
Inlet Pressure
• Inlet pressure may be low
Low
Torch Shield Not
• Torch shield may not be installed or
Installed
properly fitted
System Error
• There may be a hardware error
• Check torch and torch connections
Cause
• If the problem continues, contact the
• Contact the authorized service
• Check wire basket, reel / reel press
• If the problem continues, contact the
• Contact the authorized service
• Check remote control connections
• If the problem continues, contact the
• Contact the authorized service
• Allow the machine to cool down by
• If the problem continues, contact the
• Visually check if the fan is working
• If the problem continues, contact the
• Unblock the front of the air ducts
• If the problem continues, contact the
• Make sure that the working
• If the problem continues, contact the
• Contact the authorized service
• Check your air / gas connections,
• Make sure that the torch shield is
correctly fitted to the machine
• If the problem continues, contact the
• Contact the authorized service
COMPACT ECO SERIES
Solution
authorized service
and torch connections
authorized service
authorized service
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
authorized service
authorized service
authorized service
environment of the machine is not
excessively hot or stuffy
authorized service
make sure that the inlet pressure
is appropriate. If the inlet pressure is
normal, contact the authorized
service
authorized service
www.magmaweld.com