Safety functions
Tilt and vibration protection
If the appliance is placed inclined more than
15°, or tilts/vibrates too much due to a defect
or incorrect placement, the appliance will
immediately stop the filtration.
The power indicator and the filter indicator
flash and a continuous acoustic signal sounds.
Acoustic signal
At the end of each filtration cycle, an acoustic
signal sounds for 5 seconds. The appliance also
beeps if any error occurs. The acoustic signal can
be deactivated (see chapter "Getting started").
Over-temperature
In case of overheating (control unit >75°C),
the appliance will stop the filtration process.
The power indicator (1) flashes.
Remove the appliance from the fryer and store
it (see chapter "Storage /cooling time").
Getting started
Filtration time
The factory setting of the filtration time is
4 min. 30 sec. Up to 4 filtration cycles are possible
directly one after the other.
Checking the factory settings
1. Press and hold the Start/Stop button.
2. Plug in the power cord. Meanwhile, hold the
Start/Stop button.
3. Hold the Start/Stop button for 5 seconds.
4. Release the Start/Stop button. The filter
indicator lights up briefly.
5. The programmed filtration cycle time is
indicated by the flashing of the LEDs.
6. The power indicator shows 1 minute per flash.
7. The filter indicator shows 30 seconds per flash.
E.g.,
4 x red LED flashing = 4 min.,
1 x green LED flashing = 30 sec.
= filtration time: 4 min. 30 sec.
CU489_ML_A5_v2_20231010.indb 5
Adjusting the filtration time
To set the filtration time, follow the steps in
chapter "Checking the factory settings", then:
1. Press Start/Stop button immediately after the
filtration time is displayed.
2. Press Start/Stop button to extend the filtration
time by 30 seconds (starts at 0 second.).
(E.g. press 3x for 1 minute 30 seconds, etc.)
3. When the desired filtration cycle time has
been set, wait until the filter indicator lights up
briefly.
4. Unplug the power cord.
Adjusting the acoustic signal
To adjust the volume of the signal, follow the
instructions in chapter "Checking the factory
settings", then:
1. Wait until the filter indicator lights up briefly
and a short acoustic signal sounds.
2. Press Start/Stop button to adjust the signal.
3. The LEDs show the status:
Power indicator = Sound off
Filter indicator = Half volume
Power indicator + filter indicator = Sound on
4. When the desired setting has been made,
wait until the filter indicator lights up briefly
and an acoustic signal is audible.
5. Unplug the power cord.
EN