Charging a hot or cold battery pack
EN
If the battery pack in the charging power bank is outside
of the normal temperature range, the corresponding
battery-bay status indicator will glow solid red and
the fuel gauge on the battery pack will turn off. When
the battery pack cools down or warms up to a normal
temperature range, the battery pack will resume to
charge automatically.
Battery pack or power bank error
If the battery pack error is detected, the corresponding
battery-bay status indicator will flash red and the fuel
gauge on the battery pack will turn off.
1.
Remove and re-insert the battery pack into the
power bank. If the battery-bay status indicator still
flashes red, try charging a different battery pack that
is known to be functional.
2.
If the new replacement battery pack can be charged
normally, the original battery pack is faulty.
3.
If the battery-bay status indicator still flashes red
after trying to charge a functional battery pack, reset
the hub by unplugging the hub from power supply
and waiting until the hub-status indicator turns off.
Then reconnect the plug to the power supply.
4.
If the battery-bay status indicator still flashes red
after step 3, the power bank may be faulty.
10
56 VOLT PGX
CHARGING PORTABLE BATTERY PACKS - DC MODE
1.
2.
3.
4.
5.
6.
7.
POWER BANK — PGX1400PB
TM
Disconnect the hub from power outlet or remove the
charging cable from the power bank.
Install the high-capacity battery and the
portable battery pack, refer to the section
"CHARGING BATTERY PACKS - AC Mode".
Press the power button (for no longer than
3 seconds) and the power bank DC status indicator
and the high-capacity battery-bay status indicator
will glow green, indicating that the power bank is
working properly. The power bank will communicate
with the portable battery pack to evaluate the
condition of the battery pack. When the battery pack
meets the charging conditions, the high-capacity
battery will begin charging the portable battery
pack, and the DC status indicator and high-capacity
battery-bay status indicator will glow solid green,
and the portable battery-bay status indicator
(above the inserted battery pack) will flash green.
When two portable battery packs are connected
to the power bank, they are charged at the same
time. When the two portable battery packs are fully
charged, the portable battery-bay status indicators
will glow solid green. The "fuel gauges" on the
battery packs will turn off.
To stop DC charging mode, press the power button
again (for no longer than 3 seconds).
The DC status indicator will turn off automatically
after four hours of inactivity when the inserted
portable battery pack(s) is fully charged.
The DC status indicator will turn off automatically
after four hours when the high-capacity battery is
overheated.