SPECIFICATIONS
Display: 3 ½ digit LCD display with a max "1999"
Battery indicator: If the battery power fall under the
Operating level, a message appears on the display.
Measurement rate: 1 second, nominal.
Operating Environment: 32°F to 122°F (0°C to 50°C) at <75% humidity
Storage: -4°F to 140°F (-20°C to 60°C) at 0-80% humidity and battery is removed.
Auto Power Off: 15 seconds
DC power consumption in standby mode: <6μA
Battery: Standard 9V battery (NEDA 1604, IEC 6F22 006P).
Battery power: 9h continuous use with backlighting.
Dimensions: 148mm (H) x 105mm (W) x 42mm (T).
Weight: about 157g (including battery)
Applies to: Ferrous metals (iron, steel)
Accuracy:
+ / - 0 to 7.8 mils on 4dgts
+ / - 7dgts to 0 to 199μm
+ / - (3% + 4dgts) to 7.9 mils to 40mil (200μm to 1000μm)
Temperature coefficient:
+ / - 0.1% of the selected unit, whichever is greater. Change of accuracy in °F / °C.
Change in operate temperature above 82.4°F / 28 use °C or under 64,4°F / 18°C.
Response time: 1 second
DEFINITION
Before first use, remove the film from the calibration plate.