Descargar Imprimir esta página

Universal Blue FAMARA 4003SR Manual De Instrucciones página 35

Estufa de exterior tipo seta rattan

Publicidad

Idiomas disponibles

Idiomas disponibles

LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to
shipment. A complete gas tightness check must be performed at the
installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater.
 Make a soap solution of one part liquid detergent and one part
water. The soap solution can be applied with a spray bottle,
brush or rag. Soap bubbles will appear in case of a leak.
 The heater must be checked with a full cylinder.
 Make sure the safety control valve is in the OFF position. Turn
the gas supply ON.
 In case of a leak, turn off the gas supply. Tighten any leaking
fittings, then turn the gas supply on and re- check.
 Never leak test while smoking.
6. USING YOUR HEATER
TO TURN ON THE HEATER
Turn on the valve on the
gas
completely.
Press
variable control knob to
PILOT position (counter-
clockwise 90º).
Press down the variable
control knob and hold
for 30 seconds. While
holding
variable control knob,
press the igniter button
several times until the pilot flame lights. Release the variable
control knob after the pilot flame lights.
supply
cylinder
and
turn
down
the
the
35

Publicidad

loading

Este manual también es adecuado para:

Ucef90103-21