EDER - Powerwinch 1200 B
Storage and transport
Store the device in a clean and dry place at a temperature between -10°C
and +50 °C. Remove the battery from the battery compartment for
transport and storage. Transport the battery in electrically non-
conductive packaging.
Maintenance and faults
The battery-powered winch does not suffer from the malfunctions
specific to combustion engines. Possible faults mainly affect the
battery. The drive of the battery-powered version is maintenance-free.
No oil or other operating fluids must or may be filled into the motor unit.
Fault
LEDs on the
battery
Motor does
1 LED flashes
not start when
green.
switched on.
1 LED lights up
red.
3 LEDs flash
red.
Motor does not
4 LEDs light up
start when
red.
switched on.
Cause
Solution
Battery
Fully charge the
charge level is
battery in accordance
too low
with the operating
instructions
(charger).
Battery too
Allow battery to cool
hot or too
down or warm up.
cold
Fault in the
Remove the battery.
motor
Then: Clean the
electrical contacts in
the battery
compartment.
Reinsert the battery.
If the fault still
occurs: certified
workshop
Fault in the
Reinsert the battery.
battery.
If the fault still
occurs: certified
workshop
290206_01 | 01.2024