Astralpool PRO-ELYO INVERTER 13 Manual Del Usuario página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 169
8.1 Error code display on LED wire controller
Malfunction
Inlet water temperature sensor
failure
Outlet water temperature sensor
failure
Heating condenser sensor failure
Gas return sensor failure
Ambient temperature sensor
failure
Condenser gas exit sensor failure
Antifreeze protection in Winter
Low ambient temperature
protection
Ambient temperature is too in
heating mode
Cooling condenser
temperature too high
protection
High pressure failure
Low pressure failure
Water flow failure
8.
8.
8.
Troubleshooting
Troubleshooting
Troubleshooting
Error code
PP01
The sensor in open or short circuit
PP02
The sensor in open or short circuit
PP03
The sensor in open or short circuit
PP04
The sensor in open or short circuit
PP05
The sensor in open or short circuit
PP06
The sensor in open or short circuit
PP07
Ambient temperature or water inlet
temperature is too low
PP08
Ambient temperature or water inlet
temperature is too low
PP09
Ambient temperature is too
high
PP10
Cooling condenser
temperature is too high
EE01
1.Refrigerant is too much
2. Air flow is not enough
EE02
1.Refrigerant is not enough
2.Water flow is not enough
3. Filter jammed or capillary
jammed
EE03 or
Low water flow, wrong flow
"ON"
direction, or flow switch failure.
22
Reason
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Stop the heat pump and wait
the ambient temperature at
less than Air 50℃ ( less 5 ℃ in
allowance)
The error code will disappear
automatically
Stop the heat pump and wait
the
temperature drop down
1.Discharge redundant refrigerant
from HP gas system
2.Clean the air exchanger
1.Check if there is any gas
leakage ,re-fill the refrigerant
2.Clean the air exchanger
3.Replace the filter or capillary
Check if the water flow is enough
and flow in right direction, or else
the flow switch could be failed.
Solution
cooling
condenser

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pro-elyo inverter 21Pro-elyo inverter 35

Tabla de contenido