Descargar Imprimir esta página

Würth VP 800 Traducción Del Manual De Instrucciones De Servicio Original página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
Tool specifications
Vacuum pump
Rated voltage
UK
Rated input
Vacuum buffer
Vacuum degree
Air flow
Dimensions (L x W x H)
Weight
Tool elements
1 Air vent
2 Filter cap
3 Vacuum gauge
4 Hose clip
5 Suction hose
6 Quick coupling
7 Fluid collecting container with float
8 Mains plug
9 Machine frame
10 Spindle nut
*
11 Screw assembly
*
12 Vacuumblock fastening screw
13 Connection for vacuum pump
14 Ventilating tap
*
15 Seal
*
16 Pressure gauge vacuum kit
17 On/Off switch
*Not all of the accessories illustrated or described are included as
standard delivery.
Safety guidelines
The definitions below describe the level of severity for
each warning. Please read the operating manual and
pay attention to these symbols.
DANGER
Indicates an imminently hazardous situation
which, if not avoided, will result in death or
serious injury.
Volt ∼
220/240
Volt ∼
110/120
Watt
380
cc
2.500
mm/HG
600
L/min
128-135
cm
47 x 25 x 42
kg
13,5
*
*
*
WARNING
Indicates a potentially hazardous situation
which, if not avoided, could result in death
or serious injury.
CAUTION
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury.
NOTE
Indicates a practice not related to personal
injury which, if not avoided, may result in
property damage.
Before use
Check if the vacuum pump is connected to the
same electrical supply connector as where the
drilling machine is connected and that the voltage
is according the shield.
Check if the water-separator is empty and clean.
Start up
Position the machine horizontally. Maximum tilt
of 10°.
Fasten, mount suction hose 5 and fasten with hose
clip 4.
WARNING
Maximum drilling diameter of 122 mm.
Mount the drill stand on an even, firm and
smooth surface using the vacuum pump,
never "over" head. Always connect the core
drill and the vacuum pump to the same
power outlet. Never turn off the vacuum
pump during operation.
Install the vacuum kit.
Turn the fixation screws 21 ensuring, however,
that the seal 15 is not squeezed.
Align the drill stand.
Mount the suction hose to the connection for the
vacuum pump 13.
Close the ventilating tap 14.
Connect quick coupling 6 to vacuum kit 13 on
the drill stand.
Inserting the mains plug 8 into the socket. To turn
the machine on use On/Off switch 17.
The existing vacuum can be read from the vacuum
gauge 3.
9

Publicidad

loading

Este manual también es adecuado para:

5709 132 0