Introduction:
Industrial trucks of highly varying types are in
use in large areas and in close quarters, in halls
as well as outdoor areas.
Applications:
Important:
This line of beacons is intended for applications
where the vehicles do not leave enclosed com-
pany grounds and are not used in street traffic.
15
e.g.:
• Fork lifts
• Sweeping and construction machines
• Distribution vehicles
Technical Data
Type approval:
ECE-R10 (E9) 10R-05 16200
SAE W3-3
UL-Certifi cation (USA)
Rated voltage
12 V / 24 V
Operating voltage
10-80 V (see page 11)
Power
approx. 8 W
consumption
Dome
PC
Operating position
Upright
Protective rating
IP67, IPX9K
Temperature range minus 40 ºC to plus 60 ºC
Inverse polarity
yes
protection