Operating voltage
Current consumption
Recommended power
supply units
Max length of RS485 bus 1,000 m
Relay output
Data transmission
Max. radio range
Dimensions
Certification
Installation
12 ... 24 V DC (–15%/+10%)
80 mA
B 5494 0013 (ready for plug-in)
B 5570 0403 or B 5570 0404 for DIN rail
mounting (an additional B 5361 0020 mains
filter is required with an ixalo | SE system)
Contact load
1 A at 30 V DC
Radio frequency 868 MHz
Max. 64 radio participants
Max. 32 RS485 bus participants
20 m
Ø 55 mm, depth 30 mm Approx. 120 x 90 x 50 mm
The certificates can be found at our
website www.g-u.com.
The wall modules communicate on a frequency
that may also be used by other products. Such
products should not be mounted too close
to each other as they can interfere with each
others communication. Defective electrical
devices can also produce this frequency and be
transmitted through the wiring system. Such
interfering fields must be avoided in the vicinity
of the wall module.
In order to obtain sufficient space for the con-
necting cable, we recommend the use of flush
boxes (61 mm depth). Recommended type of
cable: J-Y(ST)Y 4 x 2 x 0.8 mm
-
30 m
9