Descargar Imprimir esta página

Blackstone 2151EU Manual Del Propietário página 11

36 piastra con cappa e ripiani pieghevol

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
Model: 2151eU
ATTACHING THe FUel CYlINdeR
ATTACHING THE REGULATOR
The regulator and hose must be connected correctly to
STEP 01
the appliance� A spanner must be used to tighten the nut onto the
connection thread�
If using a fuel clamp, attach the hose barb to the gas rail�
(Barb is left hand thread.)
(Barb is left hand thread.)
If the hose is replaced it must be secured to the appliance
STEP 02
and regulator connections with hose clips�
AVOID TWISTING THE FLExIBLE TUBE WHEN THE APPLIANCE IS IN
USE.
• ensure that the hose is not obstructed, kinked, or in contact with
any part of the appliance other than at its connection�
• Worn or damaged hose must be replaced�
• Check the rubber o-ring on the regulator end of the hose assembly
at least once a year� If it appears worn or cracked, have it replaced�
• disconnect the regulator from the cylinder (according to the direc-
tions supplied with the regulator) when the appliance is not in use�
LEAK TEST INSTRUCTIONS
Make 2-3 fluid ounces of leak detecting solution by mixing
STEP 01
one part washing up liquid with 3 parts water�
Turn off the gas supply at the gas cylinder valve�
STEP 02
ensure the control valve is "oFF"�
STEP 03
Connect the regulator to the cylinder and oN/oFF valve to
STEP 04
the burner, ensure the connections are secure then turn oN the gas�
Brush the soapy water onto the hose and all joints� If bubbles
STEP 05
appear you have a leak, which must be rectified before use� Retest
after fixing the fault�
Turn off the gas supply at the gas container after use�
STEP 06
If leakage is detected again and cannot be rectified, do NoT attempt
to cure leakage but consult your gas dealer�
BLACKSTONEPRODUCTS.COM/SUPPORT
SUPPORT BLACKSTONE EUROPE.COM
USING YOUR BLACKSTONE
LPG CYLINDER REQUIREMENTS
• Your appliance can be used
with gas cylinders between 11
kg and 15 kg�
• The maximum size of the gas
cylinder should be: dia� 320mm,
Height: 600 mm (regulator
included)�
• Follow the technical informa-
tion as stated in the instruction
manual and check with your
local gas supplier to have a
suitable gas cylinder for your
appliance�
GAS CYLINDER SAFETY
• The gas cylinder should not be dropped or handled roughly�
• If the appliance is not in use, the cylinder must be disconnected�
• Replace the protective cap on the cylinder after disconnecting the
cylinder from the appliance�
• The gas cylinder must be sited outside the body of the appliance�
• Always connect or replace the cylinder in a well-ventilated area
and away from any source of ignition, never in the presence of a
flame, spark or heat source�
• Cylinders must be stored outdoors in an upright position and out
of the reach of children� The cylinder must never be stored where
temperatures can reach over 50°C� do NoT store the cylinder near
flames, pilot lights or other sources of ignition� do NoT SMoKe�
• Make sure that the gas cylinder compartment (if any) is not
obstructed, keep it ventilated and clean�
• You will need to have the cylinder serviced or replaced every ten
years� The date of the last service should be stamped on the neck of
the bottle�
• When used on the ground always place the appliance and cylinder
on flat level ground�
| OWNER'S MANUAL
600 mm
600 mm
320 mm
320 mm
11

Publicidad

loading