Inserting material onto the cartridge holder
1. Ensure that the cartridge holder is installed pro-
perly.
2. Trim the nozzle end of the caulk/adhesive tube.
3. Holding the tool securely, press the plunger rod re-
lease trigger to declutch and free the plunger rod.
4. Pull back the plunger rod with the handle to allow
the caulk/adhesive tube to fit inside the cartridge
holder.
5. Insert the caulk/adhesive tube.
6. Press and hold plunger rod release trigger while
pushing the plunger rod handle forward until the
plunger is against the tube.
7. Release the plunger rod release trigger
MAINTENANCE
• Always be sure that the tool is switched off and
the battery pack is removed from the tool before
attempting to perform inspection or maintenance.
• Regularly clean the tool's air vents with compres-
PARTS LIST
TECHNICAL SPECIFICATIONS
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20V
Battery Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Ah/4Ah/6Ah (Li-ion) (not included)
Charge time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100mins
Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5-8 mm/s (30-480 mm/min)
Max thrust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500N
Cartridge capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300ml
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.56kg
sed dry air. Do not attempt to clean by inserting
pointed objects through openings.
• Do not use cleaning agents to clean the plastic
parts of the tool, a mild detergent on a damp cloth
is recommended instead.
• Keep plunger rod, cartridge holder and cartridge
clean of material. Retracting a plunger rod that is
covered with dried material may damage the in-
ternal parts of the tool and cause misalignment of
tube.
• Dispose the recyclable li-ion batteries properly.
NUM
1
2
3
4
5
6
7
8
9
10
11
12
· 6 ·
REF. 60032
DESCRIPTION
Cartridge holder
Plunger
Plunger rod
Plunger rod handle
Plunger rod release trigger
Variable speed dial
Trigger switch
Trigger switch lock-off
LED light
Battery release button
Battery
Charger

Publicidad