Function

The condensate fl ows through
the feed line (1) into the Q
MAT unit and accumulates in
the container (2). A capacitive
sensor (3) continuously registers
the liquid level and passes a
signal to the electronic control
as soon as the container is
fi lled. The pilot valve (4) is then
activated and the diaphragm
(5) opens the outlet line (6) for
discharging the condensate.
When the Q MAT unit has been emptied, the
outlet line is closed again quickly and tightly
without wasting compressed air.
Alarm
1 1
Valve
TEST
Power
Alarm
2 2
Valve
TEST
Power
Ready for operation - Power on
1 1
Discharge procedure - Outlet line open
2 2
Malfunction - Alarm mode activated
3 3
Test - Manual drainage/alarm
4 4
To check for correct function using the
test button:
P
RESS THE TEST BUTTON
S
HORT
>1
MIN
4
Quincy Compressor-Q MAT 04/Q MAT HP 725 Condensate Drain
1
3
2
Alarm
3 3
Valve
TEST
Power
Alarm
TEST
Valve
4 4
Power
:
E
:
FFECT
M
ANUAL DRAINAGE
A
LARM MODE
When the micro controller registers a
malfunction, the device will automatically
change to the alarm mode. The switching
sequence of the valve continues until the fault is
cleared (automatically or through maintenance).
The red LED fl ashes as long as the device is in
the alarm mode.
Malfunctioning could be caused by:
Mistakes during installation
Dropping below the necessary minimum
pressure
Excessive condensate quantities
(overloading)
Blocked/shut off outlet line
Extreme amount of dirt particles
Frozen piping
If the fault is not cleared within the fi rst minute,
a fault signal is triggered (see illustration) which
can be picked off as a potential-free signal via
the alarm relay. (24 Vdc version: pages 14-15)