User Manual
Operating Instructions
External triggering of an additional lubrication cycle
PCB 9
Pushbutton for external triggering of an additional lubrication
cycle
Fault indication
The signal output takes place with the right-side LED (pos. 3)
4 times flashing signal
System
Fault:
Signal output
Change to the factory set-
ting if signal is ignored
To remedy a fault
IMPORTANT
The pump must be checked by triggering an
additional lubrication cycle.
6001a02
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
20002458
Rotary switch (pos. 2 or 4)
LED, right-side (pos. 3)
Rotary switch on switching posi-
tion 0
4 times flashing signal, motor runs
along with flashing frequency
Press pushbutton > 2 seconds.
1)
and is implemented as follows:
3 times flashing signal
System
Fault:
Signal output
1) see fig. PCB 8
2)
In the case of a fault, check whether the centralized lubri-
cation pump and the connected system are malfunctioning.
Eliminate the cause of the fault (see chapter "Trouble-
shooting").
2.6EN-28006-E11
Pushbutton (pos. 5)
LED, right-side (pos. 3)
Short-circuit at the pushbutton or at
the connection to the external illu-
minated pushbutton.
3 times flashing signal, motor runs
along with flashing frequency