Lincoln Quicklub V10 Instrucciones De Funcionamiento página 35

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Subject to modifications
Connection X1: Square-type plug DIN 43650 (left) 1A1.01
1A1.01: Socket with cable, 3-core for power supply 24 VDC
2A1.01: Socket to connect the illuminated pushbutton (for additional lubrication and functional test) and the signal lamp in case of low-level indication
15
- Power supply + 24 VDC via machine contact
30
- bridged with 15
31
- – 0 VDC
A
- Control p.c.b. V10-V13
B
- Pump housing
C
- Connection plug 1A1.01 at pump housing
D
- Socket X1
F
- Machine contact
H
- external lamp for functional test
I
- external key for operational test and additional lubrication
K
- Connection plug 2A1.01 at pump housing
L
- Socket X3
M
- Electric motor
N
- Level control
O
- external signal lamp in case of low-level indication
Z
- Operational test / additional lubrication
Connection X3: Square-type plug DIN 43650 (right) 2A1.01
br
- brown
gb
- yellow
sw
- black
ws
- white
rt
- red
bl
- blue
gr
- grey
IMPORTANT
Do not connect the socket D with
contact 30, since the control
p.c.b. is connected internally
6001a02
between 15 and 30.
T-PCBvw-050a08

Publicidad

Tabla de contenido
loading