7. Starting, operation
Specifications
Pressure ranges
Over pressure safety
Burst pressure
Pressure ranges
Over pressure safety
Burst pressure
Materials
Wetted parts
Case
Power supply U
B
Signal output and
maximum ohmic load R
A
Adjustability zero
Response time (10 ... 90 %)
Insulation voltage
Accuracy
1-year stability
Betriebsanleitung/Operating instructions/Mode d'emploi/Instrucciones de servicio
Model P3298
bar
1,600
2,500
bar
2,300
3,500
bar
4,000
6,000
psi
23,000
36,000
psi
33,300
50,500
psi
58,000
87,000
Up to 15,000 bar / 217,000 psi on request
1.4534
Stainless steel
U
in VDC
10 ... 30 (14 ... 30 with signal output 0 ... 10 V)
B
R
in Ohm
4 ... 20 mA, 2-wire
A
0 ... 5 V, 3-wire
0 ... 10 V, 3-wire
Other signal output on request
%
5 using potentiometers inside the instrument
ms
1
VDC
500
% of span
0.5 *
)
% of span
0.25 *
*
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
)
error of measurement per IEC 61298-2).
% of span
0.1
4,000
5,000
5,000
6,000
8,000
10,000
58,000
72,000
72,500
87,000
116,000 145,000 159,500 159,500 174,000 174,000
on request
)
(at reference conditions)
6,000
7,000
8,000
7,000
8,000
10,000
11,000
11,000
12,000
87,000
100,000 115,000 145,000
101,500 116,000 145,000 159,500
R
(U
– 10 V) / 0.02 A
A
B
RA > 5,000
RA > 10,000
GB
10,000
11,000
12,000
23