Descargar Imprimir esta página

Taurus IS 1000 M Manual Del Usuario página 58

Inversor eléctrico

Publicidad

Idiomas disponibles

Idiomas disponibles

F55
DC busbar voltage is too high
F56
DC busbar voltage is too low
IGBT heat sink high
F64
Heat sink temperature is too
Note:
1. Serial number of the inverter;
2.
3.
4.
5. Your contact details.
temperature
high
1. Check PV input voltage and Ubus voltage via LCD or
monitoring platform;
2. Disconnect DC switch and AC switch, and reconnect DC
switch and AC switch 10min later to restart the inverter;
3. If the fault still exists, please contact us for help.
1. Check PV input voltage and Ubus voltage via LCD or
monitoring platform;
2. Disconnect DC switch and AC switch, and reconnect DC
switch and AC switch 10min later to restart the inverter;
3. If the fault still exists, please contact us for help.
1. Check whether the work environment temperature is too high;
2. Turn off the inverter for 10mins and restart;
3. Seek help from us, if can't go back to normal state.
- 35 -

Publicidad

loading

Este manual también es adecuado para:

Is 3000 mIs 1500 mIs 2600 m