Apply power to DV090/DV120. Turn the humidity control to a low RH% level to initiate a dehumidification
call. Confirm that the DV090/DV120 compressor and fan turn on. The furnace blower will also turn on to
circulate air. This will take up to two minutes. Be sure to turn the control to the desired RH% or to Off when
checkout is complete.
If using for ventilation, initiate a call for ventilation. Confirm that the DV090/DV120 fan turned on, but that
the compressor remained off.
Cleaning
On an annual basis, perform the following maintenance requirement to ensure the dehumidifier runs at peak
efficiency.
Unplug DV090/
1
DV120 before
beginning
service. Remove
the magnetic
filter door.
Check the drain connection and drain
3
line to ensure it is clear of debris and
sludge. Ensure all hose connections
are secure once maintenance of the
drain lines is complete.
DV090/DV120 Dehumidification System 33-00547ES—01
Remove filter
2
and replace
with new filter.
When service is complete, initiate a
4
call for dehumidification and check
that the compressor and fan activate.
If your thermostat has maintenance
reminders, reset those.