110079923 BDAL Berner BHAB 2300E-1 DL2.qxp_110079923 BDAL Berner BHAB 2300E-1 DL2 06.11.23 15:30 Seite 12
Preset programmes
Programme Temp. °C
1
250
2
350
3
450
4
550
µ
5. Memory function
The values selected for the four programmes can be
changed and memorised at any time. To do this, first press
the program button "P"
program you wish to change. Set the temperature and
airflow rate you require. Memory symbol
flashes to indicate that the user programme selected has
been changed. To memorise this setting in the user pro-
gramme selected, press and hold down the programme
selector button. The memory symbol continues to flash for
approx. 2 sec. The settings entered are saved once the
memory symbol stays on all the time. To return to normal
operation, press the program button until the program
symbol disappears from the display. To return to normal
operation, press the program button until the program
symbol disappears from the display. See page 2.
6. Changing the power cord
If the power cord is damaged, it can easily be changed
without opening the casing.
1. Important! Disconnect tool from power supply.
2. Undo screw and pull off cover cap .
3. Release cable grip .
4. Undo mains terminals .
5. Pull out cable.
6. Insert new cable and secure in reverse order
(1. Firmly screw down mains terminals etc.).
Recommendation: for safety reasons, the power cord must
only be replaced by a qualified electrician, the manufacturer,
its customer service department or by a person with similar
qualifications.
Air l/min
Application
approx. 350 Shaping plastic pipes
approx. 400 Welding plastics
approx. 500 Paint stripping
approx. 400 Soft soldering:
[S]
µ
until the display shows the
on the LCD
Tool features
³
Stainless steel outlet nozzle
·
Air inlet with lattice guard keeps out foreign matter
»
Removable guard sleeve
(for places that are hard to reach)
¿
Soft stand
´
Soft end cap
²
Heavy-duty rubber-insulated power cord
¶
Multiple-stage switch (2-stage/3-stage)
º
Joystick (for setting airflow rate and temperature)
¾
Button for airflow rate mode
µ
Programme selector button and memory button
¸
LED indicator for monitoring temperature
¹
Soft grip handle for comfortable operation
Hanging loop
Residual heat indicator
Replaceable mains power cord
- 12 -