10 MAINTENANCE
Good preventive maintenance and regular inspection ensure
long working life. In the table below you will find a listo f inspec-
tions/maintenance operations to be programmed and executed
periodically.
Consult the TROUBLE-SHOOTING" table whenever anoma-
lies are observed in order to find the solution to the problem and
contact DEA System directly whenever the solution required is not
provided.
Description
When the opening command is given, the barrier doe-
sn't move and the electrical motor doesn't work.
When the opening command is given, the motor starts
but the boom fails to move.
The barrier doesn't perfectly stop in vertical or horizon-
tal position or pushes the supports.
La barriera non si ferma perfettamente in posizione
verticale od orizzontale oppure forza sugli appoggi.
11 PRODUCT DISPOSAL
PASS consists of materials of various types, some of which can be recycled (electrical cables, plastic, aluminum, etc. ..) while others
must be disposed of (electronic boards and components).
Proceed as follows:
1. Disconnect the barrier from power supply and completely discharge the spring;
2. Disconnect and disassemble all the accessories connected. Follow the instructions in reverse to that described in the section "Instal-
lation";
3. Remove the electronic components;
4. Sorting and disposing of the materials exactly as per the regulations in the country of sale.
WARNING In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product
must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to your local municipal col-
lection point for recycling.
32
INTERVENTION TYPE
cleaning of external surfaces
checking of screw tightening
checking of release mechanism operation
greasing of articulated joint
Checking of boom balancing
TROUBLE-SHOOTING
The operator is not receiving correct power supply. Check all connections, fuses and the
power supply cable conditions and replace or repair if necessary.
Check that the unlocking system is closed.
Check that the electronic device for the force adjust is in good conditions.
Check the boom balancing.
Adjust the mechanical limit switches.
PERIODICITY
Possible solutions
6 months
6 months
6 months
1 year
1 year