Descargar Imprimir esta página

Emerson AVENTICS 652 Instrucciones De Montaje página 19

Sensor de caudal
Ocultar thumbs Ver también para AVENTICS 652:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
6.3.3 Assembly with block assembly kit
2
Fig. 7: Assembly with block assembly kit
Series
Size
Torque
652
1
3
2.9 ± 0.2 Nm / 25 ± 2 inch-pounds
2
4
4.2 ± 0.2 Nm / 37 ± 2 inch-pounds
653
1
3
2.9 ± 0.2 Nm / 25 ± 2 inch-pounds
2
4
4.2 ± 0.2 Nm / 37 ± 2 inch-pounds
1. Align the product observing the flow direction of the measuring medium (in-
put left, output right).
2. Connect the product to the block assembly kit that matches the line.
3. Mount the product with the block assembly kit. See g Fig. 7.
4. Pressurize the line section.
5. Check the installation for tightness and correct functioning.
6.4 Connecting the electrical system
The variant with IO-Link features 1 of the following options:
• 2x switch output
• 1x IO-Link communication
• 2x analog outputs
The switch outputs at contacts 5 and 4 can be used as type NO, NC and wired ac-
cordingly. See
g 13. Technical
data.
Notes
• Circuits connected to the product must be SELV and PELV circuits.
• Observe the correct supply voltage (material protection).
• Operation only with protected low voltage (material protection).
• Protection class III electric insulation (material protection).
• of measured valuIf the product is exposed to strong electromagnetical fields:
Use shielded cables to protect against interference and electrostatic effects.
• Ensure that data lines are routed properly:
– Ensure that shielded data lines with twisted pair wires are used.
– Ensure that a proper and complete shielding concept is implemented.
– Avoid interference, e.g. from switched-mode power supplies, motors,
timed regulators and contactors: Ensure that cables are laid and wired in
an EMC-compliant manner.
– Ensure that cables are not laid in parallel with power supply cables and mo-
tor cables in cable conduits over a longer distance.
• Comply with degree of protection IP65 and IP67. The IP65 and/or IP67 degree
of protection is maintained for the product only under the following condi-
tions:
– The attached cable on the M12 port is properly installed and secured.
– The round plug connector is fastened.
• Failure to comply will result in the product not conforming to any specified IP
degree of protection.
Procedure
Depending on the variant, the product has 1 of the following connections for
power supply and outputs at the top:
• IO-Link variant:
5-pin M12x1 port. See
g 6.4.1 Connection with 5-pin M12
AVENTICS™ 652/653 | 549411-001-AD | English
• Ethernet variant:
8-pin M12x1 port. See
6.4.1 Connection with 5-pin M12 plug
1. Screw the M12x1 plug of the CON-RD connecting cable to the port. See
g Fig. 1. If the port is not used, maintain IP65 degree of protection for the
housing: Cover the port with a cap.
2. Observe the pin assignment. See g Table 4.
3. Connect the cable in accordance with its function.
4. Apply the supply voltage.
1
ð After the standby delay has elapsed (approx. 1 s), the product is in run mode
(normal operating mode).
ð The display indicates the current measuring value.
Table 4: Pin assignment M12 plug, 5-pin
1
5
2
3
6.4.2 Connection with 8-pin M12 plug
1. Screw the M12x1 plug of the CON-RD connecting cable to the port. See
g Fig. 1. If the port is not used, maintain IP65 degree of protection for the
housing: Cover the port with a cap.
2. Observe the pin assignment. See g Table 5.
3. Connect the cable in accordance with its function.
4. Apply the supply voltage.
ð After the standby delay has elapsed (approx. 1 s), the product is in run mode
(normal operating mode).
ð The display indicates the current measuring value.
Fig. 8: M12x1 connection, 8-pin (X-coded) Ethernet
Table 5: Pin assignment M12 plug, 8-pin
Contact
(M12)
1
2
3
4
7
8
5
6
plug.
g 6.4.2 Connection with 8-pin M12
Contact
Identifica-
Wire color
(M12)
tion
1
L
Brown
+
2
QA
White
4
3
M
Blue
4
C/Q
Black
1
5
Q
/QB
Yellow
2
M12
1
2
3
4
7
8
5
6
4
5
3
6
2
7
1
8
RJ45
Wire color
1
White/orange TX (+) + POE
2
Orange
3
White/green
6
Green
5
White/blue
4
Blue
7
White/brown
8
Brown
plug.
Description
Supply voltage
Analog current output 4 ... 20 mA
(scalable)
Ground, reference ground for cur-
rent output
Digital output 1 (switch output) or
IO-Link communication
Digital output 2 (switch output) or
pulse/frequency output/analog
output 4 ... 20 mA (scalable)
RJ45
1
2
3
6
5
4
7
8
8 7 6 5 4 3 2 1
Identification
10/100 Mbit
TxData+
TX (-) + POE
TxData -
RX (+) - POE
RxData+
RX (-) - POE
RxData-
POE+
POE+
POE-
POE-
19

Publicidad

loading

Este manual también es adecuado para:

Aventics 653