Descargar Imprimir esta página

RS Pro RS-380 Manual De Instrucciones página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AC Clamp Meter/English
7. HOLD
Data Hold mode
µ
8. ℃,℉,
,m,V,A,K,M,Ω,
Units of measure list
9.
Battery ICON
SPECIFICATIONS
Function
Range
(% of reading+ digits)
200 mV
2V
DC Voltage
20V
200V
600V
Input Impedance:10M
Over range protection:600V
Function
Range
(% of reading+ digits)
200mV
2V
AC Voltage
20V
200V
600V
Input Impedance: 10M
Over range protection:600V
Frequency Response:50Hz~400Hz
4
Accuracy
Resolution
± (1.5% + 2d)
0.1mV
± (1.5% + 2d)
1mV
± (1.5% + 2d)
10mV
± (1.5% + 2d)
100 mV
± (2% + 2d)
1V
Accuracy
Resolution
± (1.5% +10d)
0.1mV
± (1.5% + 8d)
1mV
± (1.5% + 8d)
10mV
± (1.5% + 8d)
100 mV
± (2.5% + 8d)
1V
Function
Range
(% of reading + digits)
20A
AC Current
200A
400A
Over range protection: Maximum input 400A
Frequency Response:50Hz~60Hz
Function
Range
(% of reading + digits)
200
2k
20k
Resistance
200k
2M
20M
Over range protection:250V rms
Function
Range
(-4℉to1400℉)
Temperature
(-20.0°Cto760.0°C)
Sensor: K Type banana plug
AC Clamp Meter/English
Accuracy
Resolution
± (2.5% + 5d)
10mA
± (2.5% + 5d)
100mA
± (3% + 5d)
1A
Accuracy
Resolution
± (1.0% + 4d)
0.1
± (1.5% + 4d)
1
± (1.5% + 4d)
10
± (1.5% + 4d)
100
1k
± (2 .5% + 4d)
± (3 % + 4d)
5 .
10k
Accuracy
Resolution
(% of reading + digits)
1℉
±(3% ±8℉)
o
±(3.0% ±5°C)
1
C
5

Publicidad

loading

Este manual también es adecuado para:

123-1935