E33.1
E33.4
E43
E55
E57
E63
E65
E74
E99.3
E99.5
E99.11
9. TROUBLESHOOTING
The system fails to come on (green LED off)
Cause
» No mains voltage at the socket.
» Faulty plug or cable.
» Line fuse blown.
» Faulty on/off switch.
» Faulty electronics.
No output power the system does not weld
Cause
»
» The system has overheated (temperature alarm -
yellow LED on).
E33.3
E40
E54
E56
E62
E64
E71
E99.2
E99.4
E99.6
Solution
» Check and repair the electrical system as needed.
» Use qualified personnel only.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Replace the faulty component.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Contact the nearest service centre to have the system repaired.
Solution
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Wait for the system to cool down without switching it off.