Energy Exchange System Cross flow fixed-plate enthalpic energy exchange core: engineered, proprietary resin-media
Certified Performance
Access Door
Insulation
Mounting Options
Blower/Motor
Filters
Defrost
Warranty
Airflow Range
Rated Airflow
Dimension
Unit Weight
Duct Connections
Electrical
TR130_200_300
Due to continuing product development, specifications are subject to change without notice.
132100_003
Product Data
TR130/TR200/TR300
composite. Provides both sensible and latent heat transfer.
See HVI Certified Ratings
Front panel opens to provide access to filters, blowers, and heat exchanger. Snap latches
and hinges provided for easy service.
One inch foil-faced fiberglass throughout.
Unit may be mounted to wall or floor joists using integral mounting flange with hanging
bracket kit provided.
A single high efficiency PSC motor directly drives two large diameter centrifugal blowers for
quiet operation.
Cleanable polyester air filters for both exhaust and fresh airstreams.
Passive frost-free design under most residential conditions. Optional defrost accessory avail-
able for severe applications and climate zones.
Ten year limited warranty on energy exchange core; two year limited warranty against de-
fects in material and workmanship on all other components.
TR130
50-140 CFM for each air-
stream.
130 CFM for each airstream at
0.2" external static pressure
(ESP)
28 3/4" wide x 20 1/8" high x
13" deep (not including duct
collars)
58 lbs.
Insulating double collars with
six inch/eight inch round con-
nections for flexible or rigid
duct work.
Power: 0.1 HP, 120 Volt,
60 Cycle, single phase, 1.2
FLA, 102 watts at 130 CFM.
Control: On-board 24 volt
transformer and relay.
TR200
100-200 CFM for each air-
stream.
200 CFM for each airstream
at 0.2" external static pres-
sure (ESP)
28 3/4" wide x 20 1/8" high
x 24" deep (not including
duct collars)
80 lbs
Insulating double collars
with six inch/eight inch
round connections for flex-
ible or rigid duct work.
Power: 0.1 HP, 120 Volt,
60 Cycle, single phase, 1.5
FLA, 157 watts at 181 CFM.
Control: On-board 24 volt
transformer and relay.
Revised 9/2018
TR300
150-300 CFM for each air-
stream.
300 CFM for each airstream
at 0.4" external static pres-
sure (ESP)
28 3/4" wide x 20 1/8" high
x 24" deep (not including
duct collars)
88 lbs.
Insulating double collars
with 8-inch oval connections
for flexible or rigid duct
work.
Power: 0.2 HP, 120 Volt,
60 Cycle, single phase, 3.3
FLA, 315 watts at 297 CFM.
Control: On-board 24 volt
transformer and relay.
© 2018 S&P