5.4 Burner chart
Refer to this overview for specifications of the individual burners.
Burner
Gas type
cap
Small
Natural gas
burner
Propane gas
Large
Natural gas
burner
Propane gas
Medium
Natural gas
burner
Propane gas
Dual
Natural gas
burner
Propane gas
Pressure
Orifice
in inch
wc
6
77
10
54
6
133
10
93
6
93
10
66
6
NG:
10
¡ outer: 161
¡ inner: 74
PG:
¡ outer: 105
¡ inner: 39
Place the maintop onto the cooktop base and tilt it up
10.
from the front. Plug in the grounding connection.
Reinstall the maintop.
Reinstall the control knobs.
11.
Replace all burner bases, burner caps and burner
12.
grates.
Continue the installation procedure from
13.
→ "Connection overview", Page 11
When the installation is complete, verify that the
14.
appliance works properly.
→ "Checking the installation", Page 13 .
Note: In the event of damage, the valve must be
completely replaced.
BTU/h
kW
3,400
1.00
3,400
1.00
10,300
3.00
10,300
3.00
5,000
1.45
5,000
1.45
17,000
5.00
14,500
4.30
Conversion to LP gas en-us
M (valve
adjustment
screw setting)
17