Problem
Possible
Cause
Corrective
Action
Burner blows out
1. Burner defects.
2. Low on gas
supply.
Low heat, natural
Not right length of
gas
gas line.
Low heat
generated
with
knob in "HI"
position
1. Burner is blocked.
2. Hose not properly
assembled.
3. Low gas pressure.
1. Check for any burner defects
and proper
burner installation.
2. Make sure the gas supply is sufficient.
Follow the recommendations
in the chart
below.
From House to Grill
Distance
Tubing Size
Up to 25 ft.
3/8 in. diameter
26 -50 ft.
1/2 in. diameter
1/3 of the run:l/2
in. diameter.
51 -100 ft.
2/3 of the run:3/4 in. diameter.
1. Make certain the problem is isolated to only
one burner. If it appears so, clean the
orifice and burner, clearing ports of any
obstruction.
2. Check for a bent or kinked fuel hose.
3. Check for proper gas supply and pressure.