6. Maintenance / Repairs
The vehicle owner must arrange for the appliance to be serviced at least every 2 years from date of
purchase, including its gas supply and ducting for the products of combustion.
All maintenance and repairs must be carried out by a registered gas engineer at a Whale
Approved Service Centre or by a member of the Whale Service Engineer Network.
For installation or service information, please contact the Technical Support helpline:
Tel: +1 616 897 2301
Email: USASales@Whalepumps.com
Guarantee claims, warranty claims and acceptance of liability will be ruled out in the event of the following:
Modifications to the appliance (including accessories)
Modifications to the exhaust duct or combustion intake
Use of replacement and accessory parts other than original Whale parts
Failure to follow the installation and operating instructions
Use of the appliance for non-leisure purposes
The heat exchanger must be replaced with a Whale original spare part every 10 years from date of
registration. See the data label on the heater for the first time it was put into service.
Disposal
This product must be disposed of in accordance with the regulations of the respective country in which it is
used. National regulations and laws must be observed.
Figure 3. Heater Data Label Example
RECOGNIZED
COMPONENT
Conforms to UL Std.60730-2-5 AND 60730-1
Cert.to CAN/CSA C22.2 NO.60730-2-5 AND 60730-1 
PCBA PART NUMBER: 784.172 / 784.173
AMBIENT OPERATION TEMP: -4±158°F(-20±70 °C)
5025705
5025708
Please note: The appliance must be installed and serviced in accordance with any relevant regulations in the
country where the appliance is installed.
!
All Whale gas products must be installed and serviced by a Qualified Gas Engineer in
accordance with the installation instructions.
!
All work must be carried out by a competent person.
Conforms to ANSI Std.Z21.20
CURRENT: 10Amps Maximum
Date Code: W/YY
HEAT AIR GTR 15
Forced air furnace for indoor/outdoor installation
Générateur d'air chaud pulsé pour installations extérieures/intérieures
Serial No/Numéro de Série:
SL15611xx-23-00000
GTR 15
Model/Modèle:
Propane
Gas Type/Type de Gaz:
11in W.C.
Gas Pressure/Gaz Pression:
Nominal Heat Input/Apport Calorifique Nominal:
4,300 Btu/hr
- Low/Faible:
10,500 Btu/hr
- Medium/Moyen:
14,200 Btu/hr
- High/Haut:
Max current draw/Consommation de courant max:
Figure 4: Supplementary Certification Label
-17-
5024903
Conforms to ANSI Std.Z21.47
Certified to CSA Std.2.3
Manufactured by
2 Enterprise Road, Bangor
BT19 7TA, Northern Ireland
UK Tel: +44 (0)345 9090 911
12V d.c.
6.5A
US Tel: +1 616 897 2301
EN

Publicidad

loading

Este manual también es adecuado para:

Heat air sl15611 serieHeat air gtr 10Heat air gtr 15