Installation
Instructions
[_
CONNECT AND RUN THE VALVE
DRAIN HOSE {CONT.)
• Elevating the drain hose may cause back
pressure that could reduce the brine draw during
recharge. If raising the drain line overhead
is
required to get to the drain point, measure the
inlet water pressure to the softener first. For inlet
pressures between 20 and 50 psi, do not raise
higher than 8' above the floor. For inlet pressure
above 50 psi, the drain line mall be raised to a
maximum
height of 14'.
Dra
fittings
on valve
Valve
drain
hose
Clamp
le or wire
hose
in place
STANDPIPE
LAUNDRY TUB
SUMP
11//' air gap
FLOOR
DRAIN
CONNECTING
A RIGID VALVE DRAIN TUBE
To adapt a copper drain tube to the softener, use
a hacksaw to cut the barbed end from the drain
fitting as shown. Rotate the drain fitting so the
cutting
blade clears the valve housing to prevent
damage to valve. Bull a compression
fitting (1/4"
female pipe thread x 1/2" O.D. tube) and needed
tubing from llour local hardware
store.
1/4" NPT
threads
0.0. co er
:::i!
tube
(not provided)
CIi
Cut barbs
from
drain
fitting
Compression
fitting
1/4" NPT x 1/2" O.D.
tube
(not provided)
I-_
INSTALL THE BRINE TANK
OVERFLOW FITTINGS AND HOSE
• Insert the rubber grommet
into the 3/4" diameter
hole in the brine tank sidewall as shown.
• Push the end of the hose adapter elbow into the
grommet
as shown.
• Attach a length of hose (use remaining
hose from
Step 4) to the hose adapter elbow. Use a hose
clamp to hold it in place.
• Locate the other end of the hose at the drain
point. DO NOT ELEVATE this hose higher than the
elbow on the brine tank.
IMPORTANT: DO NOT TEE OVERFLOW HOSE TO
VALVE DRAIN HOSE.
NOTE: This drain is for safetll onlll. If the cabinet
(brine tank) should over-fill with water, the excess is
carried to the drain.
Grommet
Overflow
drain
hose
Hose
adapter
Hose
clamp
Do not connect
to valve
drain
hose.
To acceptable
drain

Publicidad