Oil Alarm System - GENERGY ISASA Instrucciones De Uso

Generador gasolina
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Once the equipments are unplugged, press the overload protector, going to the
"ON" position to restore the group voltage output.
If the overload protector trips again after connecting the devices, do not plug the
device. The plugged device may have a problem or exceeds the generator's
power.
NOTE: Once you verify that the generator cannot support or accept the
load, please do not insist. Constant overloads may negatively affect the
generator.
Remember that many equipments need extra consumption for startup.
Equipments that use an engine such as compressors, water pumps, circular
saws or others consume up to 3 times more power for startup. For example, a
500W water pump will need 1500W to start up, therefore we would need a
generator no less than 1500W.

6.4 Oil alarm system.

The oil alarm system is designed to avoid engine damaged caused by an
insufficient amount of oil in the sump. Before the oil level in the engine sump is
below the safety limit, the oil alert system will shut the engine down
automatically.
NOTE: Protection due to lack of oil must be considered extreme safety. It is
the sole responsibility of the user to check the oil level before each use as
indicated in the manual. It is unlikely for this safety to fail, but if it does, damage
230V OVERLOAD PROTECTOR
15

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido