Descargar Imprimir esta página

Husky 3332741 Guía De Uso Y Cuidado página 8

Compresor de aire de 27 galones

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance
Draining the tank
Turn off the compressor.
Pull the safety valve pull ring (I) to remove all air
pressure from the tank. Continue to hold the safety
valve open until both pressure gauges show 0 PSI.
Next, unplug the air compressor from the power source.
Position a suitable container below the drain valve.
Fully open the drain valve (K).
Keep the compressor tilted until all moisture has been
removed.
Completely close the drain valve (K).
Failure to unplug the air compressor and
WARNING:
depressurize the tank before removing the valve
may cause serious personal injury.
Because condensate is a polltant, dispose of it
NOTE:
in compliance with local regulations.
K
CLOSE
OPEN
Checking the safty valve
Turn on the air compressor and wait for the tank to ll.
The compressor automatically shuts off when the pressure
reaches the preset maximum.
Turn off the compressor.
Pull the ring on the safety valve (I) for 20 seconds to
release the air.
Release the ring. Air stops escaping at approximately
40-100 PSI. If the safety valve does not reset, stop
dispelling air between 40-100 PSI, discontinue use, and
seek service before using the air compressor again.
Do not tamper with the safty valve, Items
DANGER:
loosened from this device could y up and hit you.
Failure to heed this warning could result in death or
serious personal injury. The safety valve automatically
releases air when the receiver pressure exceeds the
preset maximum. Cheak the valve.
Air leaks after releasing the safty valve
WARNING:
ring or if the valve is stuck. Do not use the air
compressor until the safety valve has been replaced.
Using the air compressor in this condition could result
in seious personal injury.
8
Please contact 1-888-HD-HUSKY for further assistance.
I
HUSKYOOLS.COM

Publicidad

loading

Este manual también es adecuado para:

1007318721