16 / EN
No.
Description
1
RELIEF ALIVE
2
HOOKS
3
ANCHORS
4
NPT ADAPTERS
IV.- HEATER LOCATION
For optimal performance, place the heater as close as possible to the points of use
(we recommend not more than a 10 meter distance). This will minimize the loss of
heat and provide hot water faster at the point of use.
•
It is an appliance that must be installed vertically to operate properly. When
the installation is finished and before filling it with water and switching on the
power supply, make sure it is e ectively vertically mounted, using a testing
instrument (such as a bubble level).
•
Install your water heater so that the control panel is not obstructed, to facilitate
its maintenance and operation leave a free space of at least 50 cm for access
to the electrical parts.
•
The water heater's location should be as practical as possible, near the areas
where hot water is used in order to avoid heat loss or freezing in areas of
extreme cold.
•
The heater requires protection against the rain, preferably a roof at a minimum
of 80 cm from the heater cover.
•
This water heater can be installed inside or in enclosed spaces, because it
does not require ventilation.
•
The heater must be perfectly fixed to avoid movement during earthquakes
and/or tremors, in order to prevent it falling from its position. It must also be
protected by a roof or niche to avoid direct contact with the rain.
•
The heater must be mounted with its support, anchors and hooks (included).
Failure to use the anchors and bolts (included), can cause damage to the
installation.
Quantity
1
2
2
2
1
1
3
3
2
2
4
4