Descargar Imprimir esta página

Lincoln Electric HARRIS PERFECTFLAME ST Instrucciones De Uso Y Seguridad página 15

Equipo de oxicombustible
Ocultar thumbs Ver también para HARRIS PERFECTFLAME ST:

Publicidad

Idiomas disponibles

Idiomas disponibles

Flame Setup – Create New Flame Setting - Follow the steps below to create a new Flame Setting
1. Ensure that the gas and fuel inlet and outlet ball valves are in the open
position to allow gas fl ow.
2. Press Create New to open the Flame Setup detail screen.
3. Select Gas Type. NOTE: This value must be set prior to starting gas fl ow
4. Optional – set the unit format (Imperial or Metric) based upon desired
fl ow units and chemistry calculations
5. Turn the Fuel dial clockwise to start the fl ow of the fuel gas. NOTE: Gas
will fl ow through Torch 1 only in Flame Setup mode.
6. Ignite the torch. Turn the Oxygen dial clockwise to start the oxygen fl ow.
NOTE: Oxygen fl ow rate display will automatically adjust as the dial is
turned
7. Continue changing fuel and oxygen fl ow rates until the desired ratio is
achieved. The Flame Type will display based upon the ratio as either
Carburizing, Oxidizing (YELLOW), or Neutral (GREEN).
8. To reset all fi elds on the screen back to the original state, press Reset
Fields.
9. Once the desired ratio is achieved, press Save. The torch will shut off
automatically.
10. Provide a name for the Flame Setting and press Enter. The system will
return to the Flame Setup screen. NOTE: Flame Setting names must
be unique.
Example fl ame setting names
15

Publicidad

loading

Este manual también es adecuado para:

Harris perfectflame mt43019464301945