9.3 Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Multi Crown
Semi-rapid
Auxiliary
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
Multi Crown
3,55
Semi-rapid
2,0
Auxiliary
1,0
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification
Type of hob
Number of gas burners
Energy efficiency per gas burner
(EE gas burner)
Gas original:
G20 (2H) 20 mbar
Gas replacement:
G30 (3+) 28-30 mbar
G31 (3+) 37 mbar
220-240 V ~ 50-60 Hz
II2H3+
G 1/2"
3
NORMAL POWER
kW
4,0
1,85
1,0
MINIMUM
POWER kW
1,4
0,6
0,33
Left rear - Semi-rapid
Right rear - Semi-rapid
Left front - Multi Crown
Right front - Auxiliary
MINIMUM POWER kW INJECTOR MARK
1,4
0,6
0,33
INJECTOR
NOMINAL GAS FLOW g/h
MARK
G30 28-30
mbar
095
258
71
145
50
73
8,7 kW
621 g/h
611 g/h
146
92
70
G31 37 mbar
254
143
71
KGS6436SX
Built-in hob
4
60.8%
63.1%
56.2%
not applicable
ENGLISH
17