Fluid Control Systems
Type 6518
Type 6519
Operating instructions
ENGLISH
To ensure that the device will function correctly, and have a
long service life, please comply with the information in
these Operating Instructions, as well as with the application
conditions and permissible data given in the Type 6518/
6519 data sheet:
• When planning the application of the device, and during its
operation, observe the general technical rules!
• Take suitable measures to prevent unintentional operation or
impermissible impairment!
• Note that lines and valves must not be unscrewed from systems
that are under pressure!
• Always switch off the voltage supply before working on the system!
• If these instructions are ignored, no liability will be accepted from
our side, and the guarantee on the device and on accessories will
also become invalid!
• Warning! The surface of the electromagnet can become very
hot during continuous operation. Danger of injury!
3/2, 5/2 or 5/3 way valve with 3/2 way pilot valve;
valve body with diaphragm, seat seals (3/2, 5/2)
or with gate valve (5/3)
• Service, supply and venting ports with G1/4 internal thread or
plug-in connection for external hose diameters of 8 mm
• Coil can be locked in 4 x 90° steps, in between which it can be
freely positioned around the armature guide tube
• Tightening torgue of the fixing nuts: max. 5 Nm
• Can be mounted in any position, preferably with the magnetic
system at the top.
• Red indicator pin shows pneumatic position: if the valve is not
switched, the pin can be pressed in; if the valve is switched , the
pin moves outwards. The indicating pin must be pushed in again
before every functional test
• Manuel override
• Media: filtered, compressed air (max. 10 µ); neutral gases
• The valve requires no maintenance

SPARE PARTS

When ordering replacements parts, please also quote the
order number of your complete appliance in addition to the
order number of the replacement parts.
Coil kit (6518, 6519)
Voltage
Power
Order no.
[V]
[W]
24 / DC
2
645 564 D
24 / 56
2
645 565 E
110 / 56
2
645 566 F
230 / 56
2
645 567 G
Set of armature (6518, 6519)
Order no.
131 603 S
3/2-way pneumatic valve
(6518)
Connection WW
1)
Order no.
G 1/4
C
132 500 Y
G 1/4
D
132 502 N
NPT 1/4
C
132 503 P
NPT 1/4
D
132 505 R
1)
see symbols
CIRCUIT FUNCTION
C (3/2):
Output 2 normally closed when de-energised
C (Vakuum) (3/2):
auxiliary control air; output 2 normally closed
when de-energised
Warning! The vacuum generator must be connected to connection 1
D (3/2):
Pressure inlet 1 normally connected to outlet
port 2 when de-energised
H (5/2):
Pressure inlet 1 normally connected to outlet
port 2 when de-energised, outlet port 4 vented
5/2:
pilot version
L (5/3):
all ports closed in mid-position
N (5/3):
outlet ports 2 and 4 vented in mid-position;
pressure inlet 1 blocked
We reserve the right to make technical changes without
notice
© © © © © Bürkert Werke GmbH Co. All rights reserved
Voltage, electrical power, pressure range and nominal
diameter are specified on the rating plate
Voltage tolerance: ±10 %
• Electrical connection: unit socket type 2508 to tag connector of
coil (protection class IP 65);
fixing torque: 1 Nm
• When screwing down the unit socket onto the coil, ensure that the
flat seal is well seated!
• Attention! Jammed coils can cause coil overheating with AC!
Work on the unit must only be performed by skilled
personnel using suitable tools!
• Clean the pipe runs before fitting the valve!
• Observe the direction of flow!
• Never use the valve as a lever when screwing in the pipe
connections!
• Do not subject the valve housing to stress when fitting!
• Faults can be caused by dirt, short-circuits or interruptions in the
voltage
• In the event of fault, check the port connections, voltages, type of
current and operating pressures
5/2- or 5/3 way pneumatic valve
(6519)
1)
Connection
WW
Order no.
G 1/4
H
132 498 J
NPT 1/4
H
132 499 K
G 1/4 *
H
635 467 S
G 1/4 *
L
635 468 B
G 1/4 *
N
635 469 C
* This model is fitted with 2 coil sets
and 2 armature sets.
TYPE 6518 / 6519
BÜRKERT GERMANY
Chr.-Bürkert-Straße 13-17 Berlin
74653 Ingelfingen
Ph: (0 79 40) 10-0
Fax (0 79 40) 10-204
BÜRKERT INTERNATIONAL
A
Ph.
(01) 8 94 13 33
Type
AUS
Ph.
(02) 96 74 61 66
B
Ph.
(03) 3 25 89 00
5/2
CDN
Ph.
(9 05) 8 47 55 66
CH
Ph.
(0 41) 7 85 66 66
5/2
CZ
Ph.
(06 41) 22 61 80
5/2
DK
Ph.
(0 44) 50 75 00
5/3
E
Ph.
(93) 3 71 08 58
5/3
ET
Ph.
(0 40) 54 27 38
F
Ph.
(01) 48 10 31 10
GB
Ph.
(0 14 53) 73 13 53
HKG
Ph.
24 80 12 02
I
Ph.
(02) 9 52 01 59
J
Ph.
(03) 32 47 34 11
KOR
Ph.
(02) 34 62 55 92
N
Ph.
(0 63) 84 44 10
MAL
Ph.
(04) 6 57 66 49
NL
Ph.
(0 34) 6 59 53 11
NZ
Ph.
(09) 5 70 25 39
P
Ph.
(01) 4 42 26 08
PL
Ph.
(0 22) 6 27 47 20
RC
Ph.
(02) 27 58 31 99
S
Ph.
(0 40) 66 45 100
SF
Ph.
(09) 5 49 70 600
SGP
Ph.
3 83 26 12
TR
Ph.
(02 32) 4 59 53 95
USA
Ph.
(9 49) 2 23 31 00
ZA
Ph.
(0 11) 3 97 29 00
Operating Instructions No. 803 287 01/99/02
Ph: (0 30) 67 97 17 - 0
Dortmund
Ph: (0 23 73) 96 81 - 0
Dresden
Ph: (03 59 52) 36 30 - 0
Frankfurt
Ph: (0 61 03) 94 14 - 0
Hannover
Ph: (05 11) 9 02 76 - 0
München
Ph: (0 89) 82 92 28 - 0
Stuttgart
Ph: (07 11) 4 51 10 - 0
Fax (01) 8 94 13 00
Fax (02) 96 74 61 67
Fax (03) 3 25 61 61
Fax (9 05) 8 47 90 06
Fax (0 41) 7 85 66 33
Fax (06 41) 22 61 81
Fax (0 44) 50 75 75
Fax (93) 3 71 77 44
Fax (0 40) 54 41 65
Fax (01) 48 91 90 93
Fax (0 14 53) 73 13 43
Fax 24 18 19 45
Fax (02) 9 52 90 33
Fax (03) 32 47 34 72
Fax (02) 34 62 55 94
Fax (0 63) 84 44 55
Fax (04) 6 57 21 06
Fax (0 34) 6 56 37 17
Fax (09) 5 70 25 73
Fax (01) 4 42 28 08
Fax (0 22) 6 27 47 20
Fax (02) 27 58 24 99
Fax (08) 7 24 60 22
Fax (09) 5 03 12 75
Fax 3 83 26 11
Fax (02 32) 4 59 76 94
Fax (9 49) 2 23 31 98
Fax (0 11) 3 97 44 28

Publicidad

loading

Este manual también es adecuado para:

6519