Status information
The status information appears at the bottom of the screen. Common status
information prompts include:
Status information
ok Equipment ready
Basic
Inserted
info
Chging (I=16A)
Change finished
*** User Config ***
Setting
Long Press→Ent Cfg
Error code:
Error code
ERROR ! 0C 00 01
ERROR ! 0C 00 02
ERROR ! 0C 00 03
ERROR ! 0C 00 04
ERROR ! 0C 00 05
ERROR ! 0C 00 06
ERROR ! 0C 00 09
ERROR ! 0C 00 10
ERROR ! 0C 00 11
ERROR ! 0C 00 12
ERROR ! 0C 00 13
Functional Description:
Overcurrent Protection: When the current exceeds the warning value, the control box cuts off the
power output. It automatically restarts after 10 seconds for recovery, cycling three times before it
requires a power reset for recovery.
Overvoltage Protection: Protection is activated when voltage exceeds 275V/AC. It automatically
recovers after the voltage stabilizes.
Undervoltage Protection: Protection starts when voltage falls below 100V/AC. It automatically
recovers after voltage stabilizes.
Temperature Protection: Protection is activated when the internal temperature of the control box
exceeds 85°C. It automatically recovers when the temperature drops to 75°C.
Plug Over-Temperature Protection: Protection starts when the temperature inside the plug exceeds
85°C. It automatically recovers when the temperature drops to 75°C.
Leakage Protection: Requires a power reset for recovery after leakage protection is activated.
Lightning Protection: The product includes an internal circuit designed to protect against damage
caused by lightning strikes.
Static Electricity Protection Circuit: Suppresses the generation of static electricity, accelerates the
leakage of static electricity, quickly reducing it to a minimum.
Description
OK, device ready
Connect
Charging gun inserted, connecting
Charging, I=16A
Charging completed or charging ended
User Configuration Options
Long Press to Enter Settings/Save
Description
Self-check anomaly
Grounding protection anomaly
Leakage protection
Under-voltage protection
Over-voltage protection
Temperature anomaly protection
Relay adhesion protection
Communication anomaly
Connection anomaly
Vehicle-side secondary circuit break
Abnormal charging current
Solution
Please restart
restart after the voltage stabilizes
restart after the voltage stabilizes
Will automatically recover after the
temperature normalizes
Reconnect the charging gun
Reconnect the charging gun
Contact customer service
restart after the current stabilizes
EN