Descargar Imprimir esta página

geberit MAPRESS Manual Del Usuario página 68

Ocultar thumbs Ver también para MAPRESS:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 174
EN
Maintenance interval Maintenance work
Regularly, before
use, at the start of
the working day
68
▶ Check the Geberit pressing collar and
adapter jaw for externally visible defects
such as damage, material cracks,
patches of rust and other signs of wear.
If defects are present, replace the
pressing collar and adapter jaw or have
the defects repaired by an authorised
repair shop.
• Pressing collar:
– Spray the pressing contour and joint
with a lubricant recommended by
Geberit and clean with a cloth.
– Remove deposits in the pressing
contour.
– Check that the collar joints and sliding
segments can be moved easily. If
necessary, move the joints and
segments several times until they are
able to move easily.
• Adapter jaw:
– Spray the entire adapter jaw with a
lubricant recommended by Geberit and
clean with a cloth.
– Check that the jaw levers and jaw
joints of the adapter jaw can move
easily. If necessary, move the jaw
levers several times until they are able
to move easily.
36028804990855691 © 12-2023
970.496.00.0(01)

Publicidad

loading

Este manual también es adecuado para:

691.188.00.1691.189.00.1