Preliminary Remarks; Danger Of Electric Shock - GUTMANN FONDA 2840/41 ML 830 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 104

1 PRELIMINARY REMARKS

Safety instructions
Assembly, connection, commissioning and repair may only be carried out by a speci-
alist. This specialist can determine the suitable mounting and exhaust air routing of
the cooker hood. The fastening must be suitable for the weight of the cooker hood
and the load on the substrate. Observe the pull-out values of the dowels supplied.
These have the following values depending on the substrate: Dowel Ø10 mm: Con-
crete B25 9.4 kN Wall brick Z20 5.2 KN Lime sand solid brick KSV20 4.8 KN. In the
case of other unsafe substrates, a building expert, e.g. a structural engineer or archi-
tect, must be consulted to ensure safe installation of the
cooker hood.
Risk of injury !
Sharp edges may be present in the hood body due to production. Wear protective
gloves during assembly!

Danger of electric shock !

The mains voltage must correspond to the specifications on the nameplate. This is
located in the area of the filters inside the hood. Only connect the extractor hood to a
properly installed socket outlet with earthing contact. The socket must be easily ac-
cessible after installation so that the cooker hood can be disconnected from the mains
voltage if necessary. If the appliance is permanently connected (e.g. if there is no
socket), the cooker hood may only be connected to the mains voltage by a qualified
electrician. For permanent connection, the cooker hood must be connected to a single
circuit with a disconnecting device. Switches with a contact opening of at least 3 mm
and all-pole switches, e.g. LS switches and contactors, are regarded as disconnecting
devices. Switch off the mains circuit(s) before working on the electrical connection of
the extractor hood. Before drilling fixing holes, check that no electrical cables can be
damaged by drilling. The electrical connection must be prepared so that the cooker
hood
can
easily
Exhaust air duct (for exhaust air operation)
The exhaust air must not be led into a chimney which is used for exhaust gases from
devices with fuels (e.g. gas). Official regulations for the discharge of exhaust air must
be observed. The exhaust air path must be prepared in such a way that the cooker
hood can easily be connected to it. The exhaust hose must be cooker hood can be
easily connected to it. The exhaust hose must be laid without kinks. If the extractor
hood is operated simultaneously with other room air dependent fireplaces (e.g. wood-,
gas-, oil- or coal-fired appliances) in one room during exhaust air operation, deadly
be
connected.
Local
regulations
must
be
observed.
EN
39